This website would like to remind you: Your browser (IE8) is out of date.Update your browser for more security, comfort and the best experience on this site.
×
Quote Request

Instruments

General purpose, high performance and ultracentrifuges that provide superior quality, reproducibility and reliable performance.

Avanti JXN-26 Series

Enhance your workflow with the Avanti JXN-26 high-speed centrifuge system

Experience simplified high-throughput sample processing and more control with the Avanti JXN-26 with powerful features, low heat output, imbalance tolerance and quiet performance.  

Instrument Specifications

Avanti J-XN 26 Centrifuge System Specifications
UNSPSC 41103905 
Height 86 cm (34 in); with door open 149 cm (58.5 in) 
Width 71 cm (28 in) 
Depth 86 cm (34 in) 
Weight 290 kg (640 lb) 
Friction Reduction System (FRS) Mechanical rotary vane pump reduces chamber pressure for improved performance
Max capacity volume range 6 Liters
Max speed  26,000 rpm 
Approximate noise level at max speed 57 dBA (JA 30.50 Ti rotor with chamber precooled running at 26,000 rpm)
Max heat dissipation into room (steady-state conditions) 1.5 kW (5120 Btu/hr) (JA 20 rotor running at 20,000 rpm at 4-degrees C 
Rotor ID Automatic
Set temperature  -10° C to +40° C (in 1° C increments) 
Set time 99:59 
Refrigeration system Non-CFC, non-ozone depleting refrigerant 
Rotor ID Automatic
Speed control ± 10 rpm of set speed or 0.1%, whichever is greater 
Speed range 500 to 26,000 rpm or equivalent RCF 
Temperature control ± 2° C of chamber temperature (after equilibration) 
Zonal capability Yes
Single tube sample volume range 1.5 - 1,000 mL 
Ambient temperature range 16° C to 38° C 
Clearances required 7.6 cm (3.0 in) sides; 16.0 cm (6.25 in) rear 
Door 6.1 cm (2.4 in) thick plastic resin with steel plate 
Humidity restrictions < 80% (non-condensing) 
Pollution degree 2
Rotor chamber diameter 51.3 cm (20 in) 
Time–actual display Real-time run monitoring, time elapsed, time remaining, hold
Maximum force at r max (g) 81,770 x g 
Accelertion 11 profiles
Deceleration 12 profiles

Features

Anywhere, anytime control with MobileFuge
  • Remote run setup and monitoring from your Apple® iOS and Android™ device with MobileFuge
  • ​Remote alerts and access to diagnostics


Quickly change rotors
  • Optimal working surface height for easier loading and unloading of rotors
  • Hands-free door operation for easy access to rotor chamber

 

Intuitive interface 
  • Bright, highly visible display of set and actual run conditions viewable from across the lab
  • Simultaneous view of set and actual run conditions 
  • Easy rotor selection
  • 12 acceleration / 13 deceleration rates
  • Delay start
  • Run times to 99:59; Hold and ω2t integrator for precise reproducibility

 

Safe and sustainable
  • Friction Reduction System (FRS) for quicker, quieter and cooler runs
  • Lower energy use (vs traditional centrifuges)
  • BioSafe* options
  • Dynamic rotor inertia check
  • Shorter cycle times with high-torque, Switched Reluctance (SR) drive cycle 

 

Simplified Operation
  • Ideal for shared labs and GMP environments
  • Up-to 1000 user-defined programs
  • Set up and store numerous protocols
  • Password protection for up-to 50 unique user profiles
  • Instrument networking functionality 
  • Data logging and real-time run graphing

 

Robust design for consistent results and maximum uptime
  • Ideal for shared labs and GMP environments
  • Global service and support  

 

Videos

  • Centrifuge Viral Systems Recombinant Protein Production

    Click to play  

  • New Avanti JXN Series - High Performance Centrifuge - Bioproduction

    Click to play  

  • New Avanti JXN Series - High Performance Centrifuge - Ease of Use

    Click to play  

  • New Avanti JXN Series - High Performance Centrifuge - Intro

    Click to play  

  • New Avanti JXN Series - High Performance Centrifuge - Manual Run

    Click to play  

  • New Avanti JXN Series - High Performance Centrifuge - Shared Labs

    Click to play  

  • Oldest Centrifuge

    Click to play  

  • SLAS 2013

    Click to play  

  • Products

    Flow Cytometry Instruments & Software - Clinical Diagnostics

    Show: 25 50 100 items per page.

    Info
    Part No.
    Name
    Lasers
    Detectors
    Reg
    Price
    Buy

    Flow Cytometry Instruments & Software - Research and Discovery

    Show: 25 50 100 items per page.

    Info
    Part No.
    Name
    Lasers
    Detectors
    Reg
    Price
    Buy

    Centrifuges - Clinical Diagnostics

    Show: 25 50 100 items per page.

    Info
    Part No.
    Name
    Max Speed
    gForce
    Price
    Buy

    Centrifuges

    Show: 25 50 100 items per page.

    Info
    Part No.
    Name
    Max Speed
    gForce
    Price
    Buy

    B34183

    Avanti Centrifuge JXN-26, 200 - 240V, 50/60HZ, 24A

    26,000 rpm

    Request Quote

    B38619

    Avanti Centrifuge JXN-26, 200 - 240V, 50/60HZ, 24A- IVD

    26,000 rpm

    Request Quote

    B34182

    Avanti Centrifuge JXN-26, 220V, 3-PH, 50HZ, 12A

    26,000 rpm

    Request Quote

    B38618

    Avanti Centrifuge JXN-26, 220V, 3-PH, 50HZ, 12A- IVD

    26,000 rpm

    Request Quote

    B37912

    Avanti Centrifuge JXN-26, 230V, 50HZ, 24A

    26,000 rpm

    Request Quote

    B38623

    Avanti Centrifuge JXN-26, 230V, 50HZ, 24A - IVD

    26,000 rpm

    Request Quote

    Showing 1 to 6 of 6 Results

    Adapters - Clinical Diagnostics

    Show: 25 50 100 items per page.

    Info
    Part No.
    Name
    Material
    Dimensions
    Price
    Buy

    Adapters

    Show: 25 50 100 items per page.

    Info
    Part No.
    Name
    Material
    Dimensions
    Price
    Buy

    Nucleic Acid - Clinical Diagnostics

    Show: 25 50 100 items per page.

    Info
    Part No.
    Name
    Selection Options
    Sample Types
    Volume
    Reg
    Price
    Buy

    Nucleic Acid Sample Preparation

    Show: 25 50 100 items per page.

    Info
    Part No.
    Name
    Selection Options
    Sample Types
    Volume
    Reg
    Price
    Buy

    Liquid Handling Accessories - Clinical Diagnostics

    Show: 25 50 100 items per page.

    Info
    Part No.
    Name
    Mercury Content
    Humidity
    Operating Temp Range
    Price
    Buy

    Liquid Handling Accessories

    Show: 25 50 100 items per page.

    Info
    Part No.
    Name
    Mercury Content
    Humidity
    Operating Humidity
    Operating Temp Range
    Price
    Buy

    Liquid Handling Instruments - Clinical Diagnostics

    Show: 25 50 100 items per page.

    Info
    Part No.
    Name
    Air Supply Reqs
    Base Unit Depth
    Humidity
    Temp Range
    Price
    Buy

    Liquid Handlers

    Show: 25 50 100 items per page.

    Info
    Part No.
    Name
    Air Supply Reqs
    Base Unit Depth
    Humidity
    Temp Range
    Price
    Buy

    Liquid Handling Plates - Clinical Diagnostics

    Show: 25 50 100 items per page.

    Info
    Part No.
    Name
    Color
    Material
    Packaging
    Volume
    Well Shape
    Price
    Buy

    Liquid Handling Plates

    Show: 25 50 100 items per page.

    Info
    Part No.
    Name
    Color
    Material
    Packaging
    Volume
    Well Shape
    Price
    Buy

    Liquid Handling Reservoirs - Clinical Diagnostics

    Show: 25 50 100 items per page.

    Info
    Part No.
    Name
    Reservoir Material
    Tubing
    Divisions
    Material
    Packaging
    Volume
    Price
    Buy

    Liquid Handling Reservoirs

    Show: 25 50 100 items per page.

    Info
    Part No.
    Name
    Reservoir Material
    Tubing
    Divisions
    Material
    Packaging
    Volume
    Price
    Buy

    Liquid Handling Tips - Clinical Diagnostics

    Show: 25 50 100 items per page.

    Info
    Part No.
    Name
    Capacity (Max Vol)
    Packaging
    Reg
    Price
    Buy

    Liquid Handling Tips

    Show: 25 50 100 items per page.

    Info
    Part No.
    Name
    Capacity (Max Vol)
    Packaging
    Reg
    Price
    Buy

    Particle Counter/Cell Sizing and Processing - Clinical Diagnostics

    Show: 25 50 100 items per page.

    Info
    Part No.
    Name
    Price
    Buy

    Particle Counter/Cell Sizing and Processing

    Show: 25 50 100 items per page.

    Info
    Part No.
    Name
    Price
    Buy

    Rotors - Clinical Diagnostics

    Show: 25 50 100 items per page.

    Info
    Part No.
    Name
    Max Speed
    Max RCF Atr Maxg
    kFactor
    Price
    Buy

    Rotors

    Show: 25 50 100 items per page.

    Info
    Part No.
    Name
    Max Speed
    Max RCF Atr Maxg
    kFactor
    Price
    Buy

    369687

    JA-10 Rotor, Fixed Angle, Aluminum, 6 x 500 mL, 10,000 rpm, 17,700 x g

    10,000 rpm

    17,700 x g

    3,610

    Request Quote

    360992

    JA-12 Rotor, Fixed Angle, Aluminum, Biosafety Lid, 12 x 50 mL, 12,000 rpm, 23,200 x g

    12,000 rpm

    23,200 x g

    1,244

    Request Quote

    360993

    JA-12 Rotor, Single Lock Lid, 12 x 50 mL, 12,000 rpm, 23,200 x g

    12,000 rpm

    23,200 x g

    1,244

    Request Quote

    B88555

    JA-14.50 Rotor Assembly

    14,000 rpm

    35,000

    787

    Request Quote

    B88554

    JA-14.50 Rotor Assembly, Bio-Contained

    14,000 rpm

    35,000

    787

    Request Quote

    369691

    JA-17 Rotor, Fixed Angle, Aluminum, Biosafety Lid, 14 x 50 mL, 17,000 rpm, 39,800 x g

    17,000 rpm

    39,800 x g

    690

    Request Quote

    369679

    JA-18 Rotor, Fixed Angle, Aluminum, Biosafety Lid, 10 x 100 mL, 18,000 rpm, 47,900 x g

    18,000 rpm

    47,900 x g

    566

    Request Quote

    347824

    JA-18.1 Rotor, Fixed Angle, Aluminum, 24 x 1.8 mL, 18,000 rpm, 42,100 x g

    At 45° Angle: 18,000 rpm
    At 25° Angle: 17,000 rpm

    At 45° Angle: 42,100 x g
    At 25° Angle: 36,300 x g

    Request Quote

    334831

    JA-20 Rotor, Fixed Angle, Aluminum, Biosafety Lid, 8 x 50 mL, 20,000 rpm, 48,400 x g

    20,000 rpm

    48,400 x g

    770

    Request Quote

    342095

    JA-20.1 Rotor, Fixed Angle, Aluminum, Biosafety Lid, 32 x 15 mL, 20,000 rpm, 51,500 x g

    20,000 rpm

    Outer Row: 51,500 x g
    Inner Row: 43,900 x g

    Request Quote

    334845

    JA-21 Rotor, Fixed Angle, 18 x 10 mL, 21,000 rpm, 50,400 x g

    21,000 rpm

    50,400 x g

    470

    Request Quote

    363050

    JA-25.15 Rotor, Fixed Angle, Aluminum, Biosafety Lid, 24 x 15 mL, 25,000 rpm, 74,200 x g

    25,000 rpm

    Outer Row: 74,200 x g
    Inner Row: 60,200 x g

    Request Quote

    363054

    JA-25.15 Rotor, Single Lock Lid, 24 x 15 mL, 25,000 rpm, 74,200 x g

    25,000 rpm

    Outer Row: 74,200 x g
    Inner Row: 60,200 x g

    Request Quote

    363058

    JA-25.50 Rotor, Fixed Angle, Aluminum, Biosafety Lid, 8 x 50 mL, 25,000 rpm, 75,600 x g

    25,000 rpm

    75,600 x g

    418

    Request Quote

    363055

    JA-25.50 Rotor, Single Lock Lid, 8 x 50 mL, 25,000 rpm, 75,600 x g

    25,000 rpm

    75,600 x g

    418

    Request Quote

    363420

    JA-30.50 Ti Rotor, Fixed Angle, Titanium, Biosafety Lid, 8 x 50 mL, 30,000 rpm, 108,860 x g

    30,000 rpm

    108,860 x g

    280

    Request Quote

    363421

    JA-30.50 Ti Rotor, Single Lock Lid, 8 x 50 mL, 30,000 rpm, 108,860 x g

    30,000 rpm

    108,860 x g

    280

    Request Quote

    357521

    JCF-Z Continuous Flow Rotor, Large Pellet Core, Titanium, 1,250 mL, 20,000 rpm, 39,900 x g

    20,000 rpm

    293

    Request Quote

    357544

    JCF-Z Continuous Flow Rotor, Small Pellet Core, Titanium, 240 mL, 20,000 rpm, 36,300 x g

    20,000 rpm

    281

    Request Quote

    335140

    JCF-Z Continuous Flow Rotor, Standard Pellet Core, Titanium, 660 mL, 20,000 rpm, 39,900 x g

    20,000 rpm

    100

    Request Quote

    354005

    JCF-Z Reorienting Gradient Rotor, Titanium, 1,750 mL, 20,000 rpm, 39,900 x g

    20,000 rpm

    779

    Request Quote

    369681

    J-LITE® JLA-10.500 Rotor, Fixed Angle, Aluminum, Biosafety Liquid Canisters, 6 x 500 mL, 10,000 rpm, 18,600 x g

    10,000 rpm

    18,600 x g

    2,850

    Request Quote

    363930

    J-LITE® JLA-16.250 Rotor, Fixed Angle, Aluminum, Biosafety Lid, 6 x 250 mL, 16,000 rpm, 38,400 x g

    16,000 rpm

    38,400 x g

    1,090

    Request Quote

    363934

    J-LITE® JLA-16.250 Rotor, Single Lock, 6x250mL, 16,000 rpm, 38,400 x g

    16,000 rpm

    38,400 x g

    1,090

    Request Quote

    363688

    J-LITE® JLA-8.1000 Rotor, Fixed Angle, Aluminum, 6 x 1,000 mL, 8,000 rpm, 15,970 x g

    8,000 rpm

    15,970 x g

    2,482

    Request Quote

    Showing 1 to 25 of 39 Results Next >

    Tubes & Bottles - Clinical Diagnostics

    Show: 25 50 100 items per page.

    Info
    Part No.
    Name
    Closure Type
    Dimensions
    Material
    Price
    Buy

    Tubes & Bottles

    Show: 25 50 100 items per page.

    Info
    Part No.
    Name
    Closure Type
    Dimensions
    Material
    Price
    Buy
    *BioSafe and BioSafety are terms intended to describe the enhanced biocontainment features of Beckman Coulter centrifuge products.
    Kaluza Questions & Concerns
    RNACleanXP Certificate of Analysis
    CleanSeq Certificate of Analysis
    AmpureXP Certificate of Analysis
    Quote Request
    Reach Out
    Reach Out Part 2
    Download Resource
    Kaluza 30-Day Trial