This website would like to remind you: Your browser (IE8) is out of date.Update your browser for more security, comfort and the best experience on this site.
×
Quote Request

ClearLLab

ClearLLab

The Confidence of Uncompromising Accuracy

Introducing ClearLLab*, a  CE-marked, standardized kit for leukemia and lymphoma immunophenotyping that provides consistent and accurate results to streamline your workflow.

ClearLLab allows you to maximize the accuracy of results, minimize reflex testing and sign out cases with the highest confidence.

Our standardized, CE-marked combination of conjugated antibody cocktails for the flow cytometry characterization of hematolymphoid neoplasia, used in conjunction with the FC500 flow cytometer, provides a simple workflow, accuracy and reliability. And, our CE-marking means you now have a comprehensive diagnostic panel that eliminates the need to spend extra time on the validation of individual antibodies.

*Non-Hodgkin’s Lymphoma Only

Overview

Streamlined workflow. Clear results. ClearLLab for leukemia and lymphoma immunophenotyping offers your laboratory the competitive edge.

Key Benefits
  • CE-Marked: Minimize your lab’s validation work
  • Follows Bethesda/WHO guidelines: Ensure you work according to international guidelines
  • Small kit size: Adapt your inventory to actual demand with 25 tests/vial
  • Enhanced workflow: No manual antibody cocktail preparation
  • Versatility: Can be used with peripheral blood, bone marrow, and lymph node specimens
  • Identifies major cell populations: Through using the 5-combination, 18-marker panel
Advantages

Offer clinicians a reliable leukemia and lymphoma diagnostic ready-to-use solution
Effective clinician treatment decisions rely on the accuracy of laboratory testing…but what happens when that accuracy depends on many individual reagents performing independently as well as collectively? The multiple-step process of mixing and validating single-color liquid reagents means multiple opportunities for error, not to mention time stolen from your daily workflow.

Don’t compromise on your laboratory efficiency or the effectiveness of clinical treatments. ClearLLab from Beckman Coulter provides the highest degree of reliability and accuracy due to its standardized antibody panels directed against B, T, & myeloid lineage antigens intended to identify relevant leukocyte surface molecules. Our highly stable, premixed solution cuts down on preparation and handling time, freeing up your team for your laboratory’s highest priority tasks.

Your results are our business
You want to give clinicians uncompromising test accuracy while running your laboratory with maximum efficiency. Our panels are standardized, CE-marked, and ready-to-use in five different combinations that can be easily adapted to your laboratory’s specific demands.

ClearLLab allows you to identify multiple cell types at once with precision and confidence for diagnostic reporting, while also providing your laboratory staff with a simplified workflow helping to enhance your overall laboratory efficiency and business.

Improved Efficiencies

CE-marked with standardized kits and protocol, ClearLLab enhances your laboratory workflow and maximizes resources while providing accurate leukemia and lymphoma results.

For those looking for accuracy, reliability, and to improve their lab’s workflow—ClearLLab is the antibody panel that allows laboratories to focus their valuable resources on what matters… delivering a trusted clinical diagnostic solution for their leukemia and lymphoma patients.

Benefit from the overall efficiency of ClearLLab and ultimately save on resources when compared to more costly and time-consuming single color liquid reagent methods. ClearLLab is a CE-marked, standardized kit that reduces extensive validation, minimizes the potential for errors, and preserves your lab resources for its highest priorities.

ClearLLab Standardized and Validated

Standardized and Validated
No more time-consuming, error-prone cocktail preparations. ClearLLab offers antibody panel combinations that are CE-marked. All kits come with recommended gating strategies and acquisition protocol guidelines. Ultimately, this enables you to have confidence in your test results and assurance you’re providing quality information to clinicians.

ClearLLab - Improves Lab Workflow

Improves Lab Workflow
Home-brew assays are comprised of single color reagents that need to be individually pipetted, validated and assembled into cocktail formulations. ClearLLab is a pre-validated cocktail solution that utilizes a simplified staining procedure. Our premixed formulations eliminate multiple pipetting steps, minimizing variability, and reduces resuspension to a single step.

ClearLLab - Table Workflow Efficiecy
ClearLLab - Enables Efficient Use of Resources

Enables Efficient Use of Resources
Eliminating unnecessary validation steps not only preserves the consumption of critical reagents, but also the valuable time of your laboratory staff. Thanks to ClearLLab’s CE-clearance, this pre-assembled formulation significantly reduces validation time.

ClearLLab - Flexible and Comprehensive

Flexible and Comprehensive
In order to more accurately diagnose leukemia and lymphoma, ClearLLab panels offer five different standardized antibody combinations. Use any of the five color cocktails available on the FC500 to provide a more complete view of the patient’s immunophenotype.

ClearLLab - Stability and Inventory Control

Stability and Inventory Control
Individual reagent premixes have limited stability and are prone to variability. With ClearLLab, you benefit from improved stability and reduced marker interferences. Five panel combinations allow your team to adapt inventory to actual demand.

 

Product Info

We know that your laboratory runs on accuracy and thrives on efficiency. That’s why we create products and tools that adapt to the specific needs of your team. Our focus is on the individual scientists, engineers and specialists who spend their day seeking solutions for improving lives. With your workflow in mind, we offer laboratory solutions that free up your team for creating a healthier world.

  488nm
Product Number Tube FITC PE ECD PC5.5 PC7
B66807 T-cell Tube 1 (T1)
CE - 25 Tests
CD2 CD56 CD7 CD5 CD45
B66808 T-cell Tube 2 (T2)
CE - 25 Tests
CD8 CD4 -- CD3 CD45
B66809 B-cell Tube 1 (B1)
CE - 25 Tests
kappa lambda CD19 CD5 CD45
B66810 B-cell Tube 2 (B2)
CE - 25 Tests
CD20 CD10 CD19 CD38 CD45
B66812 Myeloid Tube (M)
CE - 25 Tests
CD7 CD13 CD34 CD33 CD45

Intended Use

The ClearLLab reagents are intended for in vitro diagnostic use as a screening panel for identification of various cell populations by immunophenotyping on an FC 500 flow cytometer. These reagents are used as an aid in the differential diagnosis of hematologically abnormal patients having, or suspected of having hematopoietic neoplasia including chronic leukemia, acute leukemia, non-Hodgkin lymphoma, myeloma, myelodysplastic syndrome (MDS), and/or myeloproliferative neoplasms (MPN). The reagents can be used with peripheral whole blood (collected in K2EDTA, ACD or Heparin), bone marrow (collected in K2EDTA, ACD or Heparin) and lymph node specimens for immunophenotyping. The results should be interpreted along with additional clinical and laboratory findings. These reagents provide qualitative results for the parameters listed below:

  • ClearLLab T1: CD2, CD56, CD7, CD5, CD45
  • ClearLLab T2: CD8, CD4, CD3, CD45
  • ClearLLab B1: Kappa, Lambda, CD19, CD5, CD45
  • ClearLLab B2: CD20, CD10, CD19, CD38, CD45
  • ClearLLab M: CD7, CD13, CD34, CD33, CD45

Sample Data

ClearLLab - B-cell Tubes 1 and 2

B-cell Tubes 1 and 2
Examples of dual parameter histograms from a mature B-cell neoplasm sample for BL1 and BL2 reagents (NOTE: not all histograms shown).

PN Tube FITC PE ECD PC5.5 PC7
B66809 B-cell Tube 1 (B1) 25 Tests kappa lambda CD19 CD5 CD45
B66810 B-cell Tube 2 (B2) 25 Tests CD20 CD10 CD19 CD38 CD45

ClearLLab - T-cell Tubes 1 and 2

T-cell Tubes 1 and 2
Examples of dual parameter histograms from a mature T-cell neoplasm peripheral blood sample for TL1 and TL2 reagents (NOTE: not all histograms shown).

PN Tube FITC PE ECD PC5.5 PC7
B66807 T-cell Tube 1 (T1) 25 Tests CD2 CD56 CD7 CD5 CD45
B66808 T-cell Tube 2 (T2) 25 Tests CD8 CD4 -- CD3 CD45

ClearLLab - Myeloid Tube

Myeloid Tube
Examples of dual parameter histograms from an acute myeloid leukemia (AML) bone marrow sample for Myeloid reagents (NOTE: not all histograms shown).

PN Tube FITC PE ECD PC5.5 PC7
B66812 Myeloid Tube (M) 25 Tests CD7 CD13 CD34 CD33 CD45

Products

Instruments - Clinical Diagnostics

Show: 25 50 100 items per page.

Info
Part No.
Name
Lasers
Detectors
Reg
Price
Buy

Instruments - Research and Discovery

Show: 25 50 100 items per page.

Info
Part No.
Name
Lasers
Detectors
Reg
Price
Buy

Reagents - Clinical Diagnostics

Show: 25 50 100 items per page.

Info
Part No.
Name
Species
Form
Clone
Reg
Price
Buy

B66809

ClearLLab B1 (B-cell tube 1)

CE

£622.62

B66810

ClearLLab B2 (B-cell tube 2)

CE

£622.62

B66812

ClearLLab M (Myeloid Tube)

CE

£622.62

B66807

ClearLLab T1 (T-cell Tube 1)

CE

£622.62

B66808

ClearLLab T2 (T-cell Tube 2)

CE

£498.10

Reagents - Research and Discovery

Show: 25 50 100 items per page.

Info
Part No.
Name
Species
Form
Clone
Reg
Price
Buy

ClearLLab is available in Angola, Australia, Austria, Bahrain, Belgium, Botswana, Canada, Chile, Cote d’Ivoire, Croatia, Cyprus, Czech Republic, Denmark, Finland, France, Germany, Ghana, Greece, Hong Kong, Hungary, Iceland, India, Ireland, Italy, Kenya, Kuwait, Lesotho, Liberia, Liechtenstein, Luxembourg, Madagascar, Malawi, Malta, Mauritius, Mozambique, Namibia, Netherlands, Norway, Oman, Philippines, Poland, Portugal, Qatar, Rwanda, Saudi Arabia, Slovakia, Slovenia, South Africa, Spain, Swaziland, Sweden, Switzerland, Tanzania, Uganda, United Kingdom, Zambia and Zimbabwe.

Kaluza Questions & Concerns
RNACleanXP Certificate of Analysis
CleanSeq Certificate of Analysis
AmpureXP Certificate of Analysis
Quote Request
Reach Out
Reach Out Part 2
Download Resource
Kaluza 30-Day Trial